Weather-Resistant Top Coat
Dachin AC 720
Floor penetrant
Main Composition
A single-component coating composed of modified acrylic resin, specialty functional additives, and solvents.
Main Characteristics
The cured film exhibits excellent adhesion, hardness, gloss, and weather resistance, effectively protecting against moisture, UV radiation, and other environmental factors.
Main Applications
Designed for sealing and topcoating colored concrete, stamped concrete, and bare concrete surfaces.
Technical Specifications
Film Color and Appearance | Transparent, uniform surface with no particles, pinholes, bubbles, or wrinkles |
---|---|
Density, kg/L | 0.95±0.02 |
Non-volatile Content, % | 35±1 |
Package Specifications
Package Weight / kg | Package Volume / L |
---|---|
18 | 18.9 |
Basic Parameters
Mix Ratio | Single-component |
---|---|
Pot Life | Unused portions can be resealed and reused for subsequent applications. |
Theoretical Consumption | Approx. 5.8㎡/L @ 60μm dry film thickness |
Recoat Interval
Temperature | Surface Dry | Minimum Recoat Interval | Maximum Recoat Interval |
---|---|---|---|
10℃ | 60 minutes | 24 hours | Unlimited |
25℃ | 30 minutes | 16 hours | |
30℃ | 20 minutes | 12 hours |
Data based on standard film thickness applied to steel substrate.
Application
- Dachin AC 720 Floor Penetrating Agent can be applied via airless spray for optimal single-coat film build, or by brush/roller.
- Surface temperature must remain at least 3℃ above dew point. Optimal application temperature: 5℃-35℃, with humidity <85%.
- Ensure ventilation in enclosed spaces during application.
- Thoroughly mix the coating before use. Maintain tool cleanliness and dryness before and after application.
- Avoid contact with water, acids, or alkalis during mixing and application.
- Allow full curing for 7 days before putting the coated surface into service.
Recommended Coats
Apply 1-2 coats for a dry film thickness of 60±5μm.
Surface Preparation
Clean the substrate to remove oil, dust, and other contaminants. Ensure no acid/alkali residues or moisture condensation on the surface.
Mixing
This single-component product requires only the addition of配套 diluent. Thoroughly mix with power tools before application.
Application Methods
Application Method | Diluent | Dilution Rate | Nozzle Orifice | Pressure |
Airless Spraying | Dachin Thinner X10 | 0-10% (by paint weight) | 0.4-0.5mm | 10-15 MPa |
Air Spraying | Dachin Thinner X10 | 0-10% (by paint weight) | 1.5-2.0mm | 0.3-0.5 MPa |
Roller/Brush | Dachin Thinner X10 | 0-10% (by paint weight) | - | - |
Dilution rates are calculated by paint weight.