Cookie Consent by Free Privacy Policy Generator Dachin AC 720 Floor penetrant

Weather-Resistant Top Coat

Dachin AC 720
Floor penetrant

Main Composition

A single-component coating composed of modified acrylic resin, specialty functional additives, and solvents.

Main Characteristics

The cured film exhibits excellent adhesion, hardness, gloss, and weather resistance, effectively protecting against moisture, UV radiation, and other environmental factors.

Main Applications

Designed for sealing and topcoating colored concrete, stamped concrete, and bare concrete surfaces.

Technical Specifications

Film Color and Appearance Transparent, uniform surface with no particles, pinholes, bubbles, or wrinkles
Density, kg/L 0.95±0.02
Non-volatile Content, % 35±1

Package Specifications

Package Weight / kg Package Volume / L
18 18.9

Basic Parameters

Mix Ratio Single-component
Pot Life Unused portions can be resealed and reused for subsequent applications.
Theoretical Consumption Approx. 5.8㎡/L @ 60μm dry film thickness

Recoat Interval

Temperature Surface Dry Minimum Recoat Interval Maximum Recoat Interval
10℃ 60 minutes 24 hours Unlimited
25℃ 30 minutes 16 hours
30℃ 20 minutes 12 hours

Data based on standard film thickness applied to steel substrate.

Application

  • Dachin AC 720 Floor Penetrating Agent can be applied via airless spray for optimal single-coat film build, or by brush/roller.
  • Surface temperature must remain at least 3℃ above dew point. Optimal application temperature: 5℃-35℃, with humidity <85%.
  • Ensure ventilation in enclosed spaces during application.
  • Thoroughly mix the coating before use. Maintain tool cleanliness and dryness before and after application.
  • Avoid contact with water, acids, or alkalis during mixing and application.
  • Allow full curing for 7 days before putting the coated surface into service.

Recommended Coats

Apply 1-2 coats for a dry film thickness of 60±5μm.

Surface Preparation

Clean the substrate to remove oil, dust, and other contaminants. Ensure no acid/alkali residues or moisture condensation on the surface.

Mixing

This single-component product requires only the addition of配套 diluent. Thoroughly mix with power tools before application.

Application Methods

Application Method Diluent Dilution Rate Nozzle Orifice Pressure
Airless Spraying Dachin Thinner X10 0-10% (by paint weight) 0.4-0.5mm 10-15 MPa
Air Spraying Dachin Thinner X10 0-10% (by paint weight) 1.5-2.0mm 0.3-0.5 MPa
Roller/Brush Dachin Thinner X10 0-10% (by paint weight) - -

Dilution rates are calculated by paint weight.

TOP